C M M - 52259 J U N E 1 1 , 2 0 1 0
U S E R G U I D E
14
while supporting communications rates to 1 Mbaud. The PHY provides slope control reducing
radio frequency interference (RFI) while providing a wide common-mode range input protecting
against electro-magnetic interference (EMI). The PHY also provides short-circuit protection to
battery and ground. Refer to the PCA82C250 data sheet for further details.
The FlexCAN module in the MCF52259 provides support for the CAN protocol. The FlexCAN
module supports standard and extended identifier (ID) message formats specified in the CAN
protocol specification, revision 2.0, part B. The CAN module is disabled out of reset by default
and must be configured by user application before use.
I/O CONNECTORS
The CMM-52259 applies several IO connectors arranged around the perimeter of the board
providing access to most MCU signals. The BDM_PORT header is dedicated to development
access. The figures below show signal assignment for each IO connector. With the exception
of the BDM_PORT header at J4, the IO headers are not populated in default configurations.
Figure 7: MCU_PORT IO Header
TCLK/PSTCLK/CLKOUT/FB_CLK
UCTS2*/I2C_SCL1/USB_BUSCHG/PUC3
URTS2*/I2C_SDA1/USB_VBUSDIS/PUC2
QSPI_CS2/SYNCB/USB_DM_PDOWN/PQS5
QSPI_CS0/I2C_SDA0/UCTS1/PQS3
QSPI_CLK/I2C_SCL0/URTS1/PQS2
QSPI_DIN/I2C_SDA1/URXD1/PQS1
QSPI_DOUT/I2C_SCL1/UTXD1/PQS0
QSPI_CS3/SYNCA/USB_DP_PDOWN/PQS6