3-22 (E)
DFP-R3000
(3) Check that the teeth of the sprocket do not touch
against the both sides of the perforations (holes) of the
alignment film.
If it touches, adjust the installation of the sprocket
again.
Procedure
(1) Set the sweep times of the oscilloscope so that the
pulse width (high level) of the reference pulse (oscillo-
scope CH2).
(2) Check that the deviation A of the output waveform
(RF signal) of the oscilloscope CH1 meets the follow-
ing specifications in respect to the S correction value
in the data sheet provided with the alignment film.
Specification : A = S correction value ±0.1 DIV
(scales)
When the S correction value is + :
C portion of the signal leads B portion of the center of the
rising pulse for the amount of the correction value.
When the S correction value is _ :
C portion of the signal trails B portion of the center of the
rising pulse for the amount of the correction value.
3-4. Film Running Checking
Perforations (holes)
No touch.
Film
Tooth of sprocket
Sprocket
Tooth of sprocket
Alignment film